02Section two

The absorption cycle, in dryer terms

Five stages, drawn as the circuit actually is: an evaporator that chills the process air, an absorber that holds the vacuum, a pump that lifts liquid, a generator that takes heat, and a condenser that is not a waste-heat exchanger but the dryer's heater.

2.1 The loop

Figure 2.1Single-effect loop
SOLUTIONHEAT EXCHANGERCONDENSERprocess-air reheaterQ out → reheatGENERATORdesorber · heat appliedQ in ← electric + recoveredEVAPORATORprocess-air chillerQ in ← process airABSORBERthermal compressor inletQ out → reheat / spaceREFRIGERANT VAPORVAPORLIQUIDSOLUTION PUMP
Refrigerant in teal, solution in warm gray, concentrated solution return dashed. Select a stage below to trace its path.

The chilling duty

Evaporation

Low-pressure liquid refrigerant enters the evaporator, which in this appliance is the process-air cooling coil.

The vessel is held under deep vacuum. Water at 5 °C boils at roughly 0.87 kPa, about one hundredth of atmospheric pressure, so the refrigerant evaporates at the temperature of the process air rather than at 100 °C.

Evaporation draws latent heat out of that air. Two transfers therefore occur across the same coil face: the process air is cooled below its dew point and its moisture condenses onto the coil, while the refrigerant boils and carries that heat away as vapor.

Evaporator 5–15 °C · 0.9–1.7 kPa · heat in from process air

2.2 State points

The values below are design targets for a single-effect lithium bromide machine sized to a domestic dry cycle. They are not measured data and will move with ambient, load and control strategy.

PointMediumTemperaturePressureFunction
Evaporator inletRefrigerant liquid5–10 °C0.9–1.2 kPaFlashing; chills process air
Evaporator outletRefrigerant vapor5–10 °C0.9–1.2 kPaTo absorber
Absorber outletDilute LiBr solution35–40 °C≈ 1 kPaTo solution pump
Generator inletDilute solution70–80 °C7.4–12.3 kPaAfter solution heat exchanger
Generator outlet — vaporRefrigerant vapor80–90 °C7.4–12.3 kPaTo condenser
Generator outlet — solutionConcentrated LiBr88–95 °C7.4–12.3 kPaTo heat exchanger, then throttle
Condenser outletRefrigerant liquid40–50 °C7.4–12.3 kPaTo expansion device
Process air, coil outletAir, saturated10–15 °CAmbientTo reheat coil

2.3 The process-air loop

The absorption circuit does not dry the clothes by itself. It chills and re-warms a closed air stream, and that stream does the drying.

Figure 2.2Closed process air
  1. Drum outlet

    Warm air leaves the drum, saturated

    Carrying the moisture the load has given up, at 40–70 °C depending on regime.

  2. Evaporator

    Chilled below its dew point

    Refrigerant boiling at 5–15 °C takes sensible and latent heat out of the air. Water condenses on the coil and drains away.

  3. Condenser

    Reheated by the cycle's own reject heat

    The same heat just removed is returned to the air at 45–60 °C, leaving it warm and dry.

  4. Return

    Back to the drum

    The loop is closed. No air leaves the appliance and no duct is required.

The point of the whole design

The evaporator removes heat from the process air. The condenser puts it straight back. The only energy the appliance has to keep supplying is the small deficit — the heat that leaves with the condensate and with standing losses — plus the pump and fan work. Everything else circulates inside the loop.

2.4 Why water and lithium bromide

Working fluid pair selection

Two binary pairs dominate absorption practice: water as refrigerant with lithium bromide as absorbent, used for air conditioning and chilling; and ammonia as refrigerant with water as absorbent, used where sub-freezing evaporator temperatures are required. A clothes dryer requires the first.

  • The evaporator never needs to go below 0 °C.Process air only needs cooling to a few degrees above freezing. Water's freezing point is a constraint the duty never reaches, not a limitation.
  • Water is the refrigerant.Zero ozone-depletion potential, zero global-warming potential, non-toxic, non-flammable, inexpensive, and already present in the appliance as condensate.
  • Lithium bromide is non-volatile.The vapor leaving the generator is essentially pure water, so no analyzer or rectifier is needed. Ammonia–water systems require both to strip trace water from the vapor before condensation.
  • Ammonia is the wrong material for a home.It is toxic and flammable. Introducing an ammonia charge into a consumer laundry appliance creates a risk that no efficiency gain justifies.

The penalties accepted in exchange are deep-vacuum operation and a corrosive brine. Neither is trivial, and both are carried in the risk register at section 05 rather than dismissed here.