Core components
A vapor-compression system has four principal parts. A vapor absorption system has the same four, with the compressor replaced by a thermal loop — and then adds the systems that keep a deep vacuum and a corrosive brine alive inside a domestic appliance.
3.1 The thermal loop
Seven elements carry the cycle. Only one of them moves continuously, and it is not a compressor.
Evaporator
Water refrigerant boils at 5–15 °C under vacuum, taking latent heat out of the process air and condensing its moisture onto the coil face.
Absorber
Concentrated lithium bromide sprays over a cooled bundle, dissolving refrigerant vapor and holding the evaporator at low pressure. Reject heat is captured, not discarded.
Solution pump
A canned, magnetically coupled pump raises dilute solution from absorber to generator pressure at well under one per cent of the cycle's thermal input.
Generator (desorber)
Boils refrigerant out of solution at generator pressure. Carries a dedicated electric heater, a recovered-heat coil, or both, with an allocation valve between them.
Condenser
Rejects the cycle's high-side heat into the dehumidified process air on its way back to the drum. In this appliance it is not a waste-heat exchanger but the drying heater.
Expansion and pressure-reducing devices
A refrigerant expansion device throttles high-pressure liquid into the evaporator; a solution throttle valve returns concentrated solution from generator pressure to absorber pressure.
Solution heat exchanger
Pre-heats weak solution on its way to the generator using hot strong solution returning to the absorber, cutting external heat input and lifting thermal COP from about 0.6 to about 0.7.
Note
The evaporator and the condenser are not auxiliary heat exchangers in this appliance. They are the dryer’s cooling coil and heating coil. The process air is the working medium on their secondary side.
3.2 Systems that keep the loop alive
These are not accessories. A lithium bromide machine at 1 kPa is intolerant of air, of lint, and of any loss of concentration control; each of the following exists because its absence is a known failure mode.
Vacuum-tight shell and purge system
The loop runs below 2 kPa. A hermetic shell, elastomer-compatible seals and an automatic non-condensable purge are not accessories: without them a few grams of air will stall the machine.
Process-air circuit
Drum, variable-speed blower, two-stage lint filtration, and temperature and humidity sensing at drum outlet and drum inlet.
Condensate management
Collection sump below the evaporator, level sensing, and discharge to drain or to an evaporative reject path, with freeze protection for the discharge line.
Reject-heat circuit
Secondary air or water loop serving the absorber and, in cooling mode, sharing the space-conditioning condenser fan and its ducting.
Controller
Allocates heat among the electric heater and the recovered sources, enforces solution concentration limits against crystallization, schedules purge cycles and sequences start-up and shut-down dilution.
3.3 What the architecture deletes
A justification that counts only additions is not a justification. The following are removed from the bill of materials, and each of them removes a failure mode with it.
- Mechanical compressor and its start components
- Lubricating oil charge and oil return circuit
- Fluorinated refrigerant charge — 0 g
- Reversing valve and defrost cycle
- High-side pressure protection hardware
A note on the refrigerant charge